AnkaCATH Neurovascular Distal Access Catheter
A distal access catheter specialized for neurovascular interventions, offering enhanced pushability, trackability, and stable microcatheter support in deep cerebral vessels.
Navigate with Precision and Reach with Confidence Using the AnkaCATH
- AnkaCATH is designed for distal placement into the neurovasculature, providing intracranial support and a wide range of device compatibility.
Experience Superior Performance and Unmatched Access
- Exceptionally soft distal segment allows for excellent navigability and trackability into distal anatomy, enabling the AnkaCATH Catheter to provide support close to the treatment site.
Hybrid Design for Maximum Performance
- Hybrid Braid and Coil Design provides 1:1 push/pull control for enhanced trackability.
- Coil reinforcement provides lumen integrity, flexibility and excellent shape retention.
- Proximal variable pitch braid reinforcement provides support and torque control.

Torque Braid Overlay Provides Vital Torque Control
Sharpability
Stability
Coil
Conception
Kink Resistance Inner Layer Braided
Navigate
- Material: Constructed with a durable, biocompatible Hybrid Braid and Coil Design for enhanced stability.
- Length: Extended sheath length to facilitate access to distal vascular territories.
- Flexibility: Engineered to provide optimal flexibility while maintaining structural integrity.
- Diameter Range: Available in various sizes to accommodate different procedural needs.
- Radiopacity: Enhanced radiopacity for improved visualization under imaging.
- Kink Resistance: Superior hybrid design offers excellent resistance to kinking and deformation.
- Hemostasis: Efficient hemostatic properties to minimize blood loss during procedures.
- Compatibility: Compatible with a wide range of interventional devices and guide wires.
- Length: Extended sheath length to facilitate access to distal vascular territories.
SUPERIOR
MICROCATHETER
PERFORMANCE
& RELIABLE DEVICE
DELIVERY
- High bending resistance with excellent torque control and optimum push through from proximal shaft to the distal end.
- Available in a variety of sizes, the AnkaCATH Catheter to diverse procedural requirements, ensuring a perfect fit for every patient.
- The enhanced radiopacity of the sheath allows for excellent visualization under imaging, aiding clinicians in precise navigation and placement.
- Unique hybrid braided design provides stability and support throughout the procedure, providing a sturdy yet flexible solution for expanded vascular access.
- This design contributes to the sheath’s exceptional bending resistance, maintaining integrity even in the most demanding situations.
- The rounded tip and flexible distal zone on the Distal Access Catheter are designed for confident advancement into fragile distal vessels.
- The design of Distal Access Catheter is designed for closer placement to the treatment site. Focus on the intervention, not access challenges.
Variable Stiffness & Braided Shaft
- PE/PEBAX Outer: Balances proximal rigidity for pushability with distal softness for atraumatic navigation in neurovasculature.
- Reinforced Design: A braided core ensures torsional stability, kink resistance, and secure device passage, even in sharply curved intracranial segments.
Non-Conical Large Lumen
- Generous Inner Diameter (0.071” – 0.075”): Accommodates multiple interventional devices or larger guidewires (up to 0.035”), reducing the need for multiple catheters.
- PTFE-Lined: Low-friction lumen supports smooth device transitions, crucial in time-sensitive stroke or aneurysm care.
Revêtement distal hydrophile
- Friction Reduction: The final centimeters of the distal segment are coated with a slippery surface, easing catheter advancement or repositioning through challenging anatomies.
- Vessel Protection: Minimizes endothelial trauma and reduces the risk of vasospasm or dissection during repeated manipulations.
Radiopaque Marker & Visibility
- 1 mm Marker at 2 mm from the Distal Tip: Distinct fluoroscopic marking for precise tip placement, vital in intracranial interventions.
- Radiopaque Distal Segment: Facilitates continuous imaging guidance under X-ray to confirm safe navigation and device deployment.
Multiple Sizes & Lengths
- Proximal Profiles (4F, 5F, 6F): Offer varied support levels, addressing a range of patient anatomies and procedure complexities.
- Usable Lengths (90 cm, 120 cm): Suitable for short or extended vascular paths, from moderate to more proximal femoral/radial entry routes.
Universal Hub Connection
- Luer-Lok Hub: Securely attaches accessories (e.g., hemostatic valve, flush lines), ensuring steady control of infusions or device insertions.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | AnkaCATH Neurovascular Distal Access Catheter |
Utilisation prévue | Facilitates distal access in neurovascular interventions (e.g., stroke thrombectomy, aneurysm coiling) |
Conception du cathéter | Braided or coiled shaft for torque and push, softer distal segment for atraumatic navigation |
Matériau | Pebax/Polyamide avec renfort en acier inoxydable ou en nitinol |
Diamètre extérieur (F) | ~3F–5F (depending on product code) |
Lumière intérieure | Compatible with microcatheters (0.016–0.027” ID), or direct device passage |
Longueur de travail | ~90–125 cm (varies by code) |
Configuration des conseils | Soft, radiopaque distal tip, potentially hydrophilic coating |
Marqueurs radio-opaques | 1–2 near distal zone for precise fluoroscopic tracking |
Sheath/Guide Compatibility | Typically 6F or 7F guide catheters for proximal support |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2–3 years if stored at 15–25 °C in sealed packaging |
Indications cliniques | Intracranial thrombectomy, aneurysm coiling, distal AVM catheterization |
Contre-indications | Extremely tortuous or stenotic intracranial vessels beyond feasible access, known device material allergy |
Commande et matrice des tailles
Diamètre extérieur (F) | Longueur de travail (cm) | Lumen ID (inch) | Code produit | Notes |
3F | 90 | 0.016" | ANK-NV-3F-90-016 | Smaller OD for micro-aneurysm or distal stroke interventions |
3F | 105 | 0.016" | ANK-NV-3F-105-016 | Longer approach, same small lumen |
4F | 90 | 0.021" | ANK-NV-4F-90-021 | Common distal access for moderate neurovascular tasks |
4F | 105 | 0.021" | ANK-NV-4F-105-021 | Extended length for deeper intracranial navigation |
4F | 125 | 0.021" | ANK-NV-4F-125-021 | Max length for tall patients or complex anatomies |
5F | 105 | 0.027" | ANK-NV-5F-105-027 | Larger lumen for mechanical thrombectomy devices |
5F | 125 | 0.027" | ANK-NV-5F-125-027 | Maximum length plus wide ID for advanced neuro devices |
Produits similaires
-
Atlas Coronary Stent System Acier inoxydable
Continuer la lectureA acier inoxydable offre d'endoprothèses coronaires robuste l'intégrité structurelle et facile pour les interventions coronariennes percutanées (ICP) de routine, en conciliant rentabilité et fiabilité des performances.
-
Pars Detachable Embolization Catheter
Continuer la lectureA catheter system enabling sélectif microcatheter advancement and mécanique ou chemical embolization, featuring a distal detachable tip for avoiding catheter entrapment.
-
KinG Dispositif de revascularisation intracrânienne
Continuer la lectureA récupérateur d'endoprothèse ou restauration du débit dispositif pour les maladies aiguës accident vasculaire cérébral ischémiqueL'intervention de l'équipe d'intervention d'urgence permet de capturer et d'éliminer les gros caillots des artères intracrâniennes, rétablissant ainsi rapidement la perfusion.
-
VascuVac Technologies de thrombectomie sous vide assistée par Ai
Continuer la lectureUn système innovant utilisant la technologie assistée par l'IA pour une thrombectomie sous vide efficace, conçu pour éliminer rapidement les thrombus des vaisseaux sanguins, rétablir la circulation sanguine, et minimiser les risques de procédure dans les interventions vasculaires.