Mantis XP Thrombectomy System for Fistula
A high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
Le Mantis XP est un pharmacomechanical thrombectomy system specifically engineered for dialysis native AV fistulae. Featuring a rotationnel catheter design and sinusoidal wave geometry, Mantis XP enables rapid et efficient clot disruption, infusion, and evacuation in a single pass—helping to restore patency while minimiser potential vessel trauma in end-stage renal disease (ESRD) patients requiring continuous dialysis access.
Rotational Thrombectomy Mechanism
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
Extended Infusion Zone
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
Variable Catheter Length & Profile
- Lengths: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
Nitinol & PA/PEBAX Construction
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
Radiopacity & Visibility
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip à la proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
- Lengths: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip à la proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
Spécifications des produits
| Spécifications | Détail / Valeur |
| Nom du produit | Mantis XP Thrombectomy System |
| Utilisation prévue | High-powered mechanical thrombectomy in venous or arterial occlusions, removing large or organized clot |
| Conception du cathéter | Rotational shaft with extended reach (“XP”), integrated aspiration lumen or side port |
| Matériau | Stainless steel or nitinol core, polymer outer sheath |
| Rotational Speed Range | ~50k–120k rpm (verify final) |
| Diamètre extérieur (F) | ~6–8F (depending on model) |
| Longueur de travail | ~80–120 cm (varies by product code) |
| Compatibilité des fils-guides | Typically 0.035” |
| Stérilité | Stérile, à usage unique |
| Durée de conservation | ~2–3 years if stored at 15–25 °C in sealed packaging |
| Indications cliniques | Large clot burdens in major peripheral veins/arteries, deep venous thrombosis (DVT), acute limb ischemia |
| Contre-indications | Extremely tortuous vessels, heavily calcified segments, or known sensitivity to device materials |
Commande et matrice des tailles
| Diamètre extérieur (F) | Longueur de travail (cm) | Configuration des conseils | Code produit | Notes |
| 6F | 80 | Standard Rotational Tip | MNT-XP-6F-80-SR | Smaller OD for moderate clot loads |
| 6F | 100 | Leaf Tip | MNT-XP-6F-100-LF | Intermediate length, specialized tip for large clot |
| 7F | 80 | Standard Rotational Tip | MNT-XP-7F-80-SR | Larger OD for heavier clot burden |
| 7F | 120 | Leaf Tip | MNT-XP-7F-120-LF | Extended shaft + specialized tip for extensive occlusions |
| 8F | 100 | Standard Rotational Tip | MNT-XP-8F-100-SR | Max diameter & high rotational power for dense clots |
| 8F | 120 | Leaf Tip | MNT-XP-8F-120-LF | Extended length + leaf tip for severe multi-segment thrombosis |
Produits similaires
-

Dovi Cathéter d'aspiration Thrombus Ultra
Continuer la lectureA vide poussé cathéter d'aspiration pour aiguës ou subaiguë l'élimination des thrombus dans les lits artériels ou veineux, assurant une revascularisation rapide avec un risque minimal de fragmentation.
-

VenoNeedle® Système d'ablation par radiofréquence des petites veines
Continuer la lectureA faible consommation système thermique visant à veines en araignéeLes varices réticulaires de petite taille, les télangiectasies ou les petites varices réticulaires avec précis coagulation, évitant ainsi les grandes incisions ou les temps d'arrêt prolongés.
-

Mantis CURVE Système de thrombectomie rotationnelle pharmacomécanique par fil (OTW)
Continuer la lectureUn par câble (OTW) fusion de dispositifs rotationnel perturbation avec pharmacologique La lyse des thrombus, en éliminant efficacement les gros thrombus tout en protégeant les parois saines des vaisseaux.
-

Inca® Système de protection contre les embolies
Continuer la lectureA cathéter livrer thrombolytique agents tandis que filtre empêche l'embolisation distale, garantissant une dissolution pharmacologique plus sûre des caillots.
