Peta Décompression mécanique percutanée du disque
Conçu avec des matériaux de précision, ce dispositif peu invasif permet une décompression efficace des hernies discales, soulageant la pression sur les nerfs rachidiens et atténuant la douleur tout en favorisant un rétablissement plus rapide.
Peta Mechanical Percutaneous Disk Decompression by Invamed is an innovative, single-use system that enables mechanical nucleus removal via a percutaneous approach. Designed to relieve discogenic pain and address contained disc herniations, this mechanical device uses cutting and suction or nibbling mechanisms (depending on the specific SKU) to precisely extract nucleus pulposus tissue. By preserving annular integrity, it promotes faster patient recovery and lowers the risk of complications commonly associated with more invasive spine surgery.
Minimally Invasive Percutaneous Access
- Deployed through a small-diameter cannula or introducer, requiring only a minimal incision.
- Reduces postoperative discomfort, scarring, and risk to adjacent anatomical structures compared to open discectomies.
Mechanical Debulking Mechanism
- Utilizes a cutting, nibbling, or auger-like tip to remove nucleus material effectively from within the disc.
- Real-time tactile feedback helps the operator gauge disc removal progress, preventing over-resection.
Precise Disc Clearing & Pain Relief
- Controlled resection of excess nucleus diminishes intradiscal pressure, offering symptomatic relief for radicular pain or mild degenerative disc disease.
- Preserves annular stability, reducing re-herniation risk relative to more aggressive resection.
Single-Use, Sterile System
- Disposable device ensures consistent performance and removes the need for elaborate reprocessing or repeated sterilization cycles.
- Each kit is individually packaged sterile, facilitating safe, efficient OR workflow and reducing infection risk.
Indications polyvalentes
- Primarily intended for lumbar disc decompressions (L4-L5, L5-S1), though suitable for certain cervical or thoracic segments where contained herniations exist.
- Ideal for patients with mild-to-moderate disc prolapse, discogenic back pain, or radicular symptoms not fully resolved with conservative treatments.
Peta Mechanical Percutaneous Disk Decompression - 1
Spécifications | Détail / Valeur |
Nom du produit | Peta Mechanical Percutaneous Disk Decompression (Invamed) |
Mécanisme | Mechanical cutting, nibbling, or auger-based removal of disc nucleus material via percutaneous approach |
Device Profile | Low-profile introducer or cannula system (outer diameter often ~2–3 mm); mechanical tip integrated for disc excision |
Stérilité | Single-use, sterile-packed; typically EtO or gamma sterilized |
Longueur de travail | ~100–150 mm (depending on spinal level targeted and approach) |
Guide d'imagerie | Recommended under fluoroscopy or CT to confirm device positioning and disc material removal progress |
Intended Spine Levels | Typically L3–S1 for lumbar; consult product labeling for cervical/thoracic adaptation |
Indications cliniques | Contained disc herniations, discogenic low back pain, mild degenerative disc disease requiring mechanical decompression |
Peta Mechanical Percutaneous Disk Decompression - 2
Introducer Diameter (mm) | Working Length (mm) | Approach | Code produit | Notes |
2.0 | 100 | Posterolateral (Lumbar) | PETA-DKD-2.0-100-PL-Ti | Slender device for low-profile lumbar access; suitable for small disc spaces |
2.5 | 100–120 | Posterolateral (Lumbar) | PETA-DKD-2.5-XXX-PL-Ti | Balanced diameter enabling moderate nucleus extraction while maintaining minimal trauma |
3.0 | 120–150 | Oblique (Thoracolumbar) | PETA-DKD-3.0-XXX-OB-Ti | Larger diameter for more robust disc material removal; indicated for bigger discs |
3.0 | 120 | Anterolateral (Cervical) | PETA-DKD-3.0-120-AL-Ti | Adapted approach for cervical discs; typically used with specialized retractor systems |
Produits apparentés
-
Lasergade Laser Probes Photocoagulation
Lire la suiteA titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.
-
ICT Thérapie par compression interne
Lire la suiteICT Système de reconstruction par colmatage de fuites valvulaires
ICT est une thérapie par compression interne pour les valves veineuses dysfonctionnelles. La procédure est également appelée valvuloplastie percutanée.
-
Stella Cranial Platinum Plate
Lire la suiteA platinum cranial fixation system for neurosurgical craniotomies, providing superior biocompatibility and fiable stability in skull reconstructions or tumor resections.
-
Peta RFA Décompression discale assistée par radiofréquence percutanée
Lire la suiteUne précision...système ciblé conçu pour délivrer une énergie radiofréquence contrôlée pour ablation des nerfs, réduisant ainsi efficacement les douleur chronique en perturbant la douleur transmission du signal tout en minimisant l'impact sur les tissus environnants.