Atlas Système d'endoprothèse coronaire Acier inoxydable
A acier inoxydable offre d'endoprothèses coronaires robuste l'intégrité structurelle et facile pour les interventions coronariennes percutanées (ICP) de routine, en conciliant rentabilité et fiabilité des performances.
Le ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Spécifications générales du produit
Spécifications | Détail / Valeur |
Nom du produit | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Matériau | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Conception | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Système de livraison | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Compatibilité des fils-guides | 0.014” |
Indications | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Contre-indications | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Stérilité | Stérile (oxyde d'éthylène) |
Usage unique | Oui |
Durée de conservation | 2–3 years (based on final packaging and coating, if any) |
Température de fonctionnement | Recommended 15–25 °C for storage |
Commande détaillée en fonction de la taille et codes produits
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Code produit |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Produits apparentés
-
InWIRE Fils guides PTCA
Lire la suiteUne gamme de haute performance l'offre de fils-guides coronaires durable nitinol ou inoxydable des revêtements hydrophiles et de multiples formes de pointes pour traverser les frontières. calcifié ou complexe les lésions coronaires.
-
Delta Renal Denervation System
Lire la suiteA radiofréquence-based catheter system specialized for renal sympathetic denervation in resistant hypertension, reducing nerve activity to control blood pressure.
-
Atlas Coronary Stent Graft System
Lire la suiteA covered coronary stent system providing extraluminal sealing in perforations ou pseudoaneurysms, maintaining coronary patency while preventing extravasation.
-
AngioTEN Closure Device
Lire la suiteA percutaneous vascular closure system for arterial ou veineux access sites, enabling sécurisé hemostasis after catheterization or interventional procedures.