Mantis CURVE Système de thrombectomie rotationnelle pharmacomécanique par fil (OTW)
Un par câble (OTW) fusion de dispositifs rotationnel perturbation avec pharmacologique La lyse des thrombus, en éliminant efficacement les gros thrombus tout en protégeant les parois saines des vaisseaux.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Revêtement intérieur en PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Utilisation prévue | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Conception du cathéter | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Gamme de vitesse de rotation | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Diamètre extérieur (F) | ~5–7F, depending on model |
Longueur de travail | ~80–120 cm (varies by product code) |
Compatibilité des fils-guides | Typically 0.035” (OTW approach) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2-3 ans à 15-25 °C dans un emballage scellé |
Indications cliniques | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Contre-indications | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Commande et matrice des tailles
Diamètre extérieur (F) | Longueur de travail (cm) | Curve Tip Configuration | Code produit | Notes |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Produits apparentés
-
Atlas Venous Stent
Lire la suiteA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Lire la suiteA rotationnel system featuring a leaf tip design for mécanique fragmentation du caillot plus fort des capacités d'aspiration dans les occlusions veineuses ou artérielles profondes.
-
Extender Cathéter à ballonnet PTCA
Lire la suiteA standard haute pression ballon coronaire conçu pour prédilatation des lésions ou autonome angioplastieLes profils de gonflage sont précis et les profils de croisement sont réduits.
-
NOD Valvulotome
Lire la suiteA titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.