Stena Modulateur de débit multicouche pour l'aorte
Un spécialiste stent multicouche conçu pour moduler le flux aortiqueL'utilisation de ce système permet de réduire la pression dans le sac et de stabiliser les anévrismes sans obstruer la perfusion des branches vitales. Conçu pour remodeler l'hémodynamique dans les aortique thoracique ou abdominale pour améliorer les résultats à long terme.
Le Stena Aortic Multi-Layer Flow Modulator is an advanced, self-expandable endovascular device engineered to promote controlled blood flow and aortic remodeling in a variety of aortic pathologies. Designed with a multi-layer tubular mesh structure, this stent optimizes laminar flow while providing robust radial support, conformability, and enhanced safety for complex aortic anatomies.
Multi-Layer Tubular Mesh
- Five-Layer Design: The stent is meticulously knitted from a superalloy biomedical wire, forming five distinct layers that distribute wall stress and maintain a stable configuration.
- Flow-Mediated Healing: The mesh’s micro-porosity fosters effective laminar flow within the aorta, supporting progressive thrombosis of the aneurysm sac in aneurysmal disease and enhanced remodeling in dissection scenarios.
Superalloy Wire Construction
- Biocompatibility and Durability: The wire alloy is carefully selected for its high corrosion resistance, fatigue strength, and excellent conformability.
- Self-Expanding Mechanism: Once deployed, the stent exerts controlled radial force to ensure secure apposition against the aortic wall, minimizing the risk of device migration.
Radiopaque Tantalum Markers
- Precise Fluoroscopic Visualization: Tantalum markers at both ends facilitate accurate placement under imaging guidance, ensuring correct proximal and distal landing zones.
- Enhanced Safety: Intraoperative and follow-up imaging are streamlined, enabling clinicians to verify device expansion and position over time.
Flexible Delivery and Locking System
- Sheath Lock Mechanism: The integrated sheath lock prevents premature stent deployment, providing operators with predictable and controlled release.
- Hemostasis Valve: A specialized valve setup ensures minimal blood loss and stable guidewire management throughout the procedure.
Spécifications | Détail / Valeur |
Nom du produit | Stena Modulateur de débit multicouche pour l'aorte |
Utilisation prévue | Endovascular management of Thoracic or Abdominal Aortic Aneurysms (TAA/AAA), possible application in certain chronic dissections |
Conception | Multi-layer self-expanding stent, woven nitinol mesh conducive to flow modulation |
Material Composition | Medical-grade Nitinol (Nickel-Titanium) in layered braided architecture |
Mécanisme de déploiement | Self-expanding via sheath withdrawal; no balloon inflation required |
Système de livraison | Over-the-wire or integrated introducer system, typically 14–24F (depending on diameter) |
Force radiale | Moderate to high, ensuring stable apposition in aortic walls |
Radiopacité | Integrated radiopaque markers at proximal and distal ends |
Compatibilité MR | Conditional up to 3.0T, check labeling |
Stérilité | Sterile (EO) |
Usage unique | Oui |
Durée de conservation | Typically 3–5 years (based on real-time stability data) |
Température de fonctionnement | 15–40 °C for recommended storage and deployment conditions |
Nominal Diameter Tolerance | ±0.5 mm |
Nominal Length Tolerance | ±5 mm |
Indications cliniques | Aortic aneurysm flow modulation, sac pressure reduction, side branch perfusion maintenance |
Contre-indications | Extremely tortuous or calcified aorta that precludes safe placement; known nickel allergy, etc. |
Size-Based Ordering & Product Codes (Maximal Variety)
Outer Diameter (mm) | Stent Length (mm) | Sheath Recommendation | Code produit | Notes |
20 | 60 | ~14F | STNA-MLFM-20-60 | Suitable for mid-range AAA |
20 | 80 | ~14F | STNA-MLFM-20-80 | |
20 | 100 | ~14F | STNA-MLFM-20-100 | |
20 | 120 | ~14F | STNA-MLFM-20-120 | |
20 | 140 | ~14F | STNA-MLFM-20-140 | |
20 | 160 | ~14F | STNA-MLFM-20-160 | |
20 | 180 | ~14F | STNA-MLFM-20-180 | |
20 | 200 | ~14F | STNA-MLFM-20-200 | |
22 | 60 | ~16F | STNA-MLFM-22-60 | |
22 | 80 | ~16F | STNA-MLFM-22-80 | |
22 | 100 | ~16F | STNA-MLFM-22-100 | |
22 | 120 | ~16F | STNA-MLFM-22-120 | |
22 | 140 | ~16F | STNA-MLFM-22-140 | |
22 | 160 | ~16F | STNA-MLFM-22-160 | |
22 | 180 | ~16F | STNA-MLFM-22-180 | |
22 | 200 | ~16F | STNA-MLFM-22-200 | |
24 | 60 | ~16F or 18F | STNA-MLFM-24-60 | |
24 | 80 | ~16F or 18F | STNA-MLFM-24-80 | |
24 | 100 | ~16F or 18F | STNA-MLFM-24-100 | |
24 | 120 | ~16F or 18F | STNA-MLFM-24-120 | |
24 | 140 | ~16F or 18F | STNA-MLFM-24-140 | |
24 | 160 | ~16F or 18F | STNA-MLFM-24-160 | |
24 | 180 | ~16F or 18F | STNA-MLFM-24-180 | |
24 | 200 | ~16F or 18F | STNA-MLFM-24-200 | |
26 | 60 | ~18F | STNA-MLFM-26-60 | |
26 | 80 | ~18F | STNA-MLFM-26-80 | |
26 | 100 | ~18F | STNA-MLFM-26-100 | |
26 | 120 | ~18F | STNA-MLFM-26-120 | |
26 | 140 | ~18F | STNA-MLFM-26-140 | |
26 | 160 | ~18F | STNA-MLFM-26-160 | |
26 | 180 | ~18F | STNA-MLFM-26-180 | |
26 | 200 | ~18F | STNA-MLFM-26-200 | |
28 | 80 | ~20F | STNA-MLFM-28-80 | |
28 | 100 | ~20F | STNA-MLFM-28-100 | |
28 | 120 | ~20F | STNA-MLFM-28-120 | |
28 | 140 | ~20F | STNA-MLFM-28-140 | |
28 | 160 | ~20F | STNA-MLFM-28-160 | |
28 | 180 | ~20F | STNA-MLFM-28-180 | |
28 | 200 | ~20F | STNA-MLFM-28-200 | |
30 | 80 | ~20F or 22F | STNA-MLFM-30-80 | |
30 | 100 | ~20F or 22F | STNA-MLFM-30-100 | |
30 | 120 | ~20F or 22F | STNA-MLFM-30-120 | |
30 | 140 | ~20F or 22F | STNA-MLFM-30-140 | |
30 | 160 | ~20F or 22F | STNA-MLFM-30-160 | |
30 | 180 | ~20F or 22F | STNA-MLFM-30-180 | |
30 | 200 | ~20F or 22F | STNA-MLFM-30-200 | |
32 | 120 | ~22F | STNA-MLFM-32-120 | |
32 | 140 | ~22F | STNA-MLFM-32-140 | |
32 | 160 | ~22F | STNA-MLFM-32-160 | |
32 | 180 | ~22F | STNA-MLFM-32-180 | |
32 | 200 | ~22F | STNA-MLFM-32-200 | |
34 | 140 | ~24F | STNA-MLFM-34-140 | |
34 | 160 | ~24F | STNA-MLFM-34-160 | |
34 | 180 | ~24F | STNA-MLFM-34-180 | |
34 | 200 | ~24F | STNA-MLFM-34-200 | |
36 | 160 | ~24F | STNA-MLFM-36-160 | |
36 | 180 | ~24F | STNA-MLFM-36-180 | |
36 | 200 | ~24F | STNA-MLFM-36-200 | |
38 | 160 | ~24F | STNA-MLFM-38-160 | |
38 | 180 | ~24F | STNA-MLFM-38-180 | |
38 | 200 | ~24F | STNA-MLFM-38-200 | |
40 | 160 | ~24F | STNA-MLFM-40-160 | |
40 | 180 | ~24F | STNA-MLFM-40-180 | |
40 | 200 | ~24F | STNA-MLFM-40-200 | |
42 | 160 | ~24F | STNA-MLFM-42-160 | |
42 | 180 | ~24F | STNA-MLFM-42-180 | |
42 | 200 | ~24F | STNA-MLFM-42-200 | |
44 | 180 | ~24F | STNA-MLFM-44-180 | |
44 | 200 | ~24F | STNA-MLFM-44-200 | |
46 | 180 | ~24F | STNA-MLFM-46-180 | |
46 | 200 | ~24F | STNA-MLFM-46-200 |
Produits similaires
-
Peta Plaque de fermeture du sternum
Lire la suiteA titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.
-
JaGuar Gaine de guidage
Lire la suiteA tressé gaine de guidage fournissant couple contrôle et kink résistance à la navigation sécurisée dans les périphérique ou viscéral des interventions.
-
NeoCardia Minimally Invasive Cardiac Surgery Instruments
Lire la suitePrecision-crafted surgical tools tailored for minimally invasive cardiac procedures, enabling enhanced maneuverability, reduced trauma, and improved outcomes in delicate cardiovascular interventions.
-
Filler Agent d'embolisation à base de cyanoacrylate
Lire la suiteA cyanoacrylate adhésif embolique pour vasculaire ou AVM occlusion, offre rapide polymérisation au contact du sang, garantissant une étanchéité stable du vaisseau et un artefact minimal.