Le Horus® Optic Laser Probes by Invamed deliver high-performance photocoagulation capabilities for vitreoretinal surgery and other ophthalmic interventions. Constructed from medical-grade fiber optics, these probes offer precise laser energy transmission to the retina or posterior segment, ensuring effective photocoagulation with minimal scatter. Available in 20, 23, 25, or 27 gauge (0.81 mm, 0.64 mm, 0.50 mm, 0.41 mm), each probe caters to diverse procedural preferences and ocular anatomies.
Wide Range of Gauge Sizes
- 20G (0.81 mm), 23G (0.64 mm), 25G (0.50 mm), 27G (0.41 mm): Broad selection accommodates various surgical approaches—from standard vitrectomy ports to ultra-fine, minimally invasive surgeries.
- Surgeons can select the optimal gauge for patient-specific anatomy, pathology, and lens clarity.
High-Purity Fiber Optic Construction
- Fiber cables are derived from medical-grade fused silica or equivalent high-quality materials, ensuring superior light transmission and minimal dispersion.
- Enhanced photocoagulation precision reduces collateral tissue damage, crucial in delicate retinal structures.
Sterile & Disposable
- Probes come sterile and single-use, preventing cross-contamination and maintaining consistent optical performance.
- Simplifies OR workflow and eliminates the need for repeated reprocessing, reducing risk of fiber damage over multiple sterilization cycles.
Soft Tip & Angled Variants
- Certain models feature soft tip designs to safeguard against iatrogenic injury during retinal manipulations.
- Angled or curved tip options provide surgeons with improved access to peripheral or posterior pole lesions.
Versatile Laser Compatibility
- Standard endolaser coupling ensures broad compatibility with common ophthalmic laser systems (e.g., diode, argon).
- Color-coded or labeled connectors enable quick identification and safe, secure attachment during setup.
Indications cliniques
- Retinal photocoagulation for diabetic retinopathy, macular edema, peripheral retina tears, lattice degeneration, or choroidal neovascular membranes.
- Vitreoretinal procedures requiring localized laser application—such as panretinal photocoagulation (PRP) or focal macular treatments.
Produits similaires
-
Clever Maille non absorbable
Lire la suiteFabriqué à partir de matériaux durables et biocompatibles, ce treillis chirurgical fournit un renforcement à long terme pour la réparation des tissus mous, assurant la force et la stabilité dans des procédures telles que la réparation des hernies.
-
ATLAS Système de stent coronaire à élution médicamenteuse Cobalt Chrome
Lire la suiteA cobalt-chrome pose d'un stent coronaire résistance radiale durable et excellente traçabilité, adapté à complexe ou calcifié des lésions coronaires tout en garantissant un recul minimal.
-
Lasergade Laser Probes Photocoagulation
Lire la suiteA titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.
-
Peta Ablation par radiofréquence (RFA) pour les douleurs du genou
Lire la suiteUne précision...système ciblé conçu pour délivrer une énergie radiofréquence contrôlée pour ablation des nerfs, réduisant ainsi efficacement les douleur chronique en perturbant la douleur transmission du signal tout en minimisant l'impact sur les tissus environnants.