MultiBEAM Filtre de la veine cave inférieure (IVC)
Un véhicule convertible ou récupérable Prévention de l'utilisation du filtre IVC embolies pulmonaires en interceptant les caillots qui se déplacent dans la veine cave inférieure, ce qui garantit la sécurité des patients à haut risque.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
Contre-indications
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | MultiBEAM Filtre de la veine cave inférieure (IVC) |
Utilisation prévue | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
Mécanisme de déploiement | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
Marqueurs radio-opaques | Distal apex or anchor tips for fluoroscopic identification |
Compatibilité MR | MR Conditionnel (vérifier l'étiquetage) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~3-5 ans si stocké à 15-25 °C dans un emballage scellé |
Indications cliniques | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
Contre-indications | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
Commande et matrice des tailles
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | Code produit | Notes |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
Produits similaires
-
Extender Cathéter à ballonnet PTCA
Lire la suiteA standard haute pression ballon coronaire conçu pour prédilatation des lésions ou autonome angioplastieLes profils de gonflage sont précis et les profils de croisement sont réduits.
-
Inca Système de thrombolyse Trellis
Lire la suiteA cathéter livrer thrombolytique agents tandis que filtre empêche l'embolisation distale, garantissant une dissolution pharmacologique plus sûre des caillots.
-
Dovi Cathéter d'aspiration Thrombus Ultra
Lire la suiteA vide poussé cathéter d'aspiration pour aiguës ou subaiguë l'élimination des thrombus dans les lits artériels ou veineux, assurant une revascularisation rapide avec un risque minimal de fragmentation.
-
Viper™ Cathéters de perfusion à valve
Lire la suiteLe Viper™ Cathéter de perfusion à valve est un monolumière, pointe à clapet système de livraison qui offre la flexibilité nécessaire pour infuser agents anti-thrombus, contraste radio-opaque ou autres solutions pharmacologiques spécifiées par le médecin avec ou sans un fil-guide en place.