DolphinPro Cathéter de soutien
A aide à la traversée cathéter pour complexe des lésions périphériques ou coronaires, présentant une arbre renforcé et hydrophile pour faciliter l'administration du dispositif.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Large utilité clinique
Idéal pour femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
Contre-indications
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Spécifications techniques
Spécifications | Détail / Valeur |
Nom du produit | DolphinPro Cathéter de soutien |
Utilisation prévue | Lesion crossing and support in femoro-popliteal & BTK interventions |
Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
Compatibilité des fils-guides | Typically 0.014” or 0.018” (verify exact compatibility) |
Radiopacité | Radiopaque distal tip and markers for precise visualization |
Stérilité | Provided sterile (single use) |
Indications cliniques | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Taille et matrice de commande
Taille française | Usable Length (cm) | Guidewire | Forme de l'embout | Code produit | Notes |
2.4 – 2.6 | 65 / 90 / 135 | 0.014" | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
2.4 – 2.6 | 100 / 150 | 0.014" | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
6.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
7.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
Produits similaires
-
Système d'athérectomie TemREN PRO
Lire la suiteTemREN PRO Atherectomy System ; A rotationnel ou directionnel dispositif d'athérectomie spécialisé pour excision de la plaque dans les artères périphériques, augmentant lumen tout en minimisant le barotraumatisme.
-
Viper™ Cathéters de perfusion à valve
Lire la suiteLe Viper™ Cathéter de perfusion à valve est un monolumière, pointe à clapet système de livraison qui offre la flexibilité nécessaire pour infuser agents anti-thrombus, contraste radio-opaque ou autres solutions pharmacologiques spécifiées par le médecin avec ou sans un fil-guide en place.
-
Extender Cathéter à ballonnet PTCA à élution médicamenteuse Paclitaxel
Lire la suiteA recouvert de paclitaxel cathéter coronaire à ballonnet destiné à réduire la resténose pendant l'angioplastie coronaire transluminale percutanée (ACTP), garantissant ainsi l'administration efficace du médicament à la paroi du vaisseau.
-
Dolphin Cathéter d'entrée sub-intimale
Lire la suiteA sous-intimale système d'aide à la réinsertion dans le lumen réel après le franchissement sous-intimal dans les segments CTO ou fortement occlus, en veillant à ce que les expansions de dissection soient minimales.