روتابلیتور TemREN
الف چرخشی سیستم ترومبکتومی یا آترکتومی با ویژگی پرسرعت مته ها به آسیاب کردن یا پلاک کلسیفیه شده را حذف کنید، که باعث انبساط بهتر لومن برای قرار دادن استنت میشود.
TemRENRT Rotablator: Management of Calcified Lesions
- Maximize Stent Success with Advanced Pre-Treatment. Embarking on the treatment of calcified lesions with the TemREN Rotabilator sets the foundation for optimal stent deployment.
- By employing the power of rotational atherectomy, this leading-edge system ensures the site is ideally prepared for stenting procedures.
Presicion & Reliability of TemRENRT Rotablator
- Enhance the therapeutic arsenal with the precision and reliability of the TemREN Rotabilator, and set a new standard in patient care.
- The Temren Rotabilator is not just a tool but a comprehensive system, meticulously designed to conquer the most challenging calcified lesions with finesse and flexibility.
The Pinnacle of Atherectomy Efficiency
- System Advancer: Offers the flexibility of using multiple-sized catheter burrs independently, ensuring readiness for a diverse range of procedural demands.
- System Burrs: A versatile selection of burr sizes, from 1.25 mm to 2.50 mm,empowers clinicians to tailor their approach to the unique needs of each lesion.
Empower Your Practice with TemREN: Atherectomy at its Smartest
- کنترل: Bluetooth connectivity for remote control via Android and iOS devices.
- Artificial Intelligence: Embedded AI system for smart, data-driven operation. TemREN delivers smart, data-driven operation, further enhancing its precision and reliability.
THE ROTABLATOR SYSTEM PROVIDES
AN EXCELLENT
OPTION
OR TREATING CALCIFIED LESIONS
مشخصات عمومی محصول
مشخصات | جزئیات / ارزش |
نام محصول | TemREN RT Rotablator |
کاربرد مورد نظر | Rotational atherectomy for calcified or fibrotic plaque removal in coronary or peripheral arteries |
Burr Material | Diamond-coated or Tungsten-Carbide burr (depending on model) |
Shaft Material | Stainless steel or nickel-titanium alloy with torque-transmitting core |
Rotational Speed Range | ~60,000 to 200,000 rpm (verify exact device specs) |
Burr Diameter Range | 1.25–3.00 mm (common range for coronary use; might differ for peripheral) |
Length of Working Shaft | 135–150 cm (typical) |
سازگاری با گاید وایر | 0.009” or 0.014” (depending on burr size & design) |
Control Console | TemREN Rotablator Drive Unit (or universal system, if compatible) |
Flushing | Saline infusion or heparinized solution recommended to cool and lubricate |
استریل بودن | استریل (اتیلن اکسید) |
یکبار مصرف | بله |
ماندگاری | 2–3 years (if packaging remains sealed and intact) |
دمای عملیاتی | دمای نگهداری توصیه شده ۱۵ تا ۲۵ درجه سانتیگراد |
علائم بالینی | Severely calcified lesions, fibrotic plaque requiring mechanical debulking prior to stent/balloon |
موارد منع مصرف | Extremely tortuous or dissected vessels, unprotected left main disease, or severe vessel spasm |
Coronary Burr Range (1.25–2.00 mm)
Burr Dia (mm) | طول کار (سانتی متر) | Recommended Speed (rpm) | Guidewire | کد محصول | یادداشتها |
1.25 | 135 | 140k–180k | 0.009” | TMR-125-135-140180 | Ultra-small burr, used for extremely tight lesions |
1.50 | 135 | 140k–180k | 0.009” | TMR-150-135-140180 | Standard small burr for moderate calcification |
1.50 | 150 | 60k–160k | 0.014” | TMR-150-150-60160 | Alternate wire compatibility, longer shaft |
1.75 | 135 | 140k–180k | 0.014” | TMR-175-135-140180 | Common mid-range burr for heavier plaque |
1.75 | 150 | 80k–160k | 0.014” | TMR-175-150-80160 | Extended working length, slightly slower top rpm |
2.00 | 135 | 140k–180k | 0.014” | TMR-200-135-140180 | Largest typical coronary burr size |
2.00 | 150 | 80k–160k | 0.014” | TMR-200-150-80160 | Extended length variant, used in elongated vessels |
Peripheral Burr Range (2.00–3.00 mm)
Burr Dia (mm) | طول کار (سانتی متر) | Recommended Speed (rpm) | Guidewire | کد محصول | یادداشتها |
2.00 | 150 | 60k–140k | 0.014” | TMR-200-P-150-60140 | Peripheral version, large artery usage |
2.25 | 150 | 60k–140k | 0.014” | TMR-225-P-150-60140 | Slightly bigger burr for moderate-larger peripheral vessels |
2.50 | 150 | 50k–120k | 0.014” | TMR-250-P-150-50120 | Slower recommended top rpm, robust torque for calcification |
2.75 | 150 | 50k–120k | 0.014” | TMR-275-P-150-50120 | Heavier plaque removal in iliac or superficial femoral arteries |
3.00 | 150 | 50k–100k | 0.014” | TMR-300-P-150-50100 | Max burr diameter, typically for large, heavily calcified vessels |
2.00 | 150 | 60k–140k | 0.014” | TMR-200-P-150-60140 | Peripheral version, large artery usage |