Spider™ Sistema Periférico de Bobina Desmontable (Desmontable Empujable)

A bobina desmontable kit para embolización de aneurismas periféricos, fístulas AV o vasos anormales, proporcionando un empaquetamiento estable de la bobina con controlado desprendimiento mecánico.

The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.

Detachable Pushable Delivery

Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.

High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.

The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.

Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.

Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.

Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.

Especificaciones del producto

Especificación Detalle / Valor
Nombre del producto Spider Peripheral Detachable Coil System
Uso previsto Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels
Material de la bobina Platinum or platinum-tungsten alloy with detachable mechanism
Método de desprendimiento Mechanical or electrolytic (verify final model)
Gama de diámetros de bobina ~1.5–20 mm (varies by catalog code)
Longitud de la bobina ~1–40 cm (depending on coil diameter and framing vs. filling type)
Delivery Microcatheter Typically 2.3–2.7F inner diameter, 0.016–0.021” ID
Radiopacidad Platinum coil for fluoroscopic visualization
Esterilidad Estéril, un solo uso
Vida útil ~3–5 years at 15–25 °C
Indicaciones clínicas Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice
Contraindicaciones Vessels too small or tortuous to accommodate microcatheter, known device material allergies

Matriz de pedidos y tamaños

Diámetro de la bobina (mm) Longitud de la bobina (cm) Tipo de desprendimiento Código del producto Notas
1.5 2 Mecánica SPD-P-1.5x2-M Bobina muy pequeña para microaneurismas
1.5 4 Electrolítico SPD-P-1.5x4-E Extended length, small diameter
3.0 10 Mecánica SPD-P-3.0x10-M Mid-range coil diameter, framing type
3.0 15 Electrolítico SPD-P-3.0x15-E Longer filling coil for larger sac
5.0 15 Mecánica SPD-P-5.0x15-M Medium coil for moderate aneurysms
5.0 20 Electrolítico SPD-P-5.0x20-E Extended coil length, filling type
10.0 20 Mecánica SPD-P-10.0x20-M Larger diameter coil for bigger aneurysms
10.0 40 Electrolítico SPD-P-10.0x40-E Maximum length coil for large-volume occlusion