Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
En over-the-wire (OTW) device merging rotacional disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Revestimiento interior de PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Especificaciones del producto
| Especificación | Detalle / Valor |
| Nombre del producto | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
| Uso previsto | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
| Diseño del catéter | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
| Velocidad de rotación | ~40k–80k rpm (verify final) |
| Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
| Diámetro exterior (F) | ~5–7F, depending on model |
| Longitud de trabajo | ~80–120 cm (varies by product code) |
| Compatibilidad de guías | Typically 0.035” (OTW approach) |
| Esterilidad | Estéril, un solo uso |
| Vida útil | ~2-3 años a 15-25 °C en envase cerrado |
| Indicaciones clínicas | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
| Contraindicaciones | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Matriz de pedidos y tamaños
| Diámetro exterior (F) | Longitud de trabajo (cm) | Curve Tip Configuration | Código del producto | Notas |
| 5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
| 5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
| 6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
| 6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
| 7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
| 7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Productos relacionados
-

Extender Catéter balón PTCA liberador de fármaco Paclitaxel
Leer másA recubierto de paclitaxel catéter coronario de balón dirigido a reducir la reestenosis durante la angioplastia coronaria transluminal percutánea (ACTP), garantizando la administración eficaz del fármaco a la pared vascular.
-

ICT Terapia de compresión interna
Leer másICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-

Viper™ Catéteres de infusión con válvula
Leer másEn Viper™ Valved Infusion Catheter es un single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with o without a guidewire in place.
-

VenoNeedle® Sistema de ablación por RF de venas pequeñas
Leer másA bajo consumo sistema térmico destinado a arañas vascularestelangiectasias o pequeñas varices reticulares con preciso coagulación, evitando grandes incisiones o prolongados periodos de inactividad.
