Extender Drug Eluting PTA Balloon Catheter
Extender Drug Eluting PTA Balloon Catheter; A drug-coated balloon for peripheral transluminal angioplasty (PTA), releasing antiproliferative agents to mitigate restenosis in femoral or popliteal arteries.

Elevating Angioplasty with Precision and Efficacy
- Balloon Material: Durable and flexible for precise navigation and deployment.
- Compatibility: Usable with standard catheter systems.
- Size Range: Available in various sizes to accommodate different vascular diameters.
- Compatibility: Usable with standard catheter systems.
Choose for Optimal Drug Delivery
- Deployment: Rapid and controlled balloon inflation and deflation.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.
- Drug Coating: Homogeneous drug distribution for consistent delivery.
- Drug Type: Paclitaxel Incorporates anti-proliferative drugs to prevent restenosis.


Innovation Meets Vascular Treatment
- Highly compliant balloon material ensures optimal contact with the vessel wall foreffective drug delivery.Therapeutic window achieved after 30 seconds inflation time.Rapid drug release and absorption kinetics ensure targeted therapeutic effects,assuring physicians of sustained results.
Safety and Effectiveness of the Novel TemREN Atherectomy System Combined Use With Extender Drug-Eluting Balloon in Lower Extremity Arteries
Results
For the primary analysis, the rate of lesion technical success was 97.0%, meeting the prospectively established target performance goal of 86%. After postatherectomy adjunctive therapy, residual stenosis was 30% for 100% of lesions means final diameter stenosis, 10.9%.
Early and midterm results of the retrograde transpopliteal approach as the first-line treatment for total occlusions of iliofemoral arteries.
Results
Technical success, defined as restored patency with no stenosis greater than 30%, was achieved in (92.9%) of patients. A patient who was a heavy smoker showed acute symptoms of claudication due to 80% stenosis of the iliac stent 20 days after discharge and was treated with balloon angioplasty.
- 3.0-3.5ug / mm2 drug dosage
- <2mm particles
- Contrast media as a drug carrier
- Minimum drug release during delivery
- Available in Non-Compliant version
- <90% drug transfer to the target lession
- Quick deflation time
- Excellent pushability
General Product Specifications
Specification Detail / Value Product Name Extender Drug PTA Balloon Catheter (Paclitaxel- or Sirolimus-coated, depending on your actual platform) Intended Use Percutaneous transluminal angioplasty (PTA) in peripheral arteries (e.g., femoral, popliteal, tibial) to reduce restenosis Balloon Material Semi-/Non-Compliant polymer (Nylon, Pebax) with drug coating Drug Coating Paclitaxel or alternative antiproliferative agent (x µg/mm²) Nominal Inflation Pressure ~6–10 atm (depends on diameter) Rated Burst Pressure (RBP) ~12–16 atm (depending on balloon size) Catheter Shaft Length Typically 80–150 cm (adjust for your product line) Guidewire Compatibility 0.018” or 0.035” (commonly for peripheral balloons—verify actual design) Coating Release Rapid drug release upon inflation (~30–60 seconds recommended inflation time) Sterility Sterile (Ethylene Oxide) Single Use Yes Vida útil 2–3 years if stored at 15–25 °C in sealed packaging Clinical Indications PAD (peripheral artery disease), femoropopliteal lesions, below-the-knee disease, in-stent restenosis in peripheral arteries Contraindicaciones Highly calcified lesions requiring atherectomy first, allergic reaction to drug coating, severely tortuous or occluded vessels Diameter Range 1.5–6.0 mm (For smaller vessels, BTK or moderate femoral)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) Product Code 1.5 20 6 12 ~200 EXD-PTA-1.5x20 1.5 40 6 12 ~400 EXD-PTA-1.5x40 2.0 40 7 14 ~600 EXD-PTA-2.0x40 2.0 60 7 14 ~900 EXD-PTA-2.0x60 2.5 80 8 14 ~1200 EXD-PTA-2.5x80 3.0 80 8 14 ~1500 EXD-PTA-3.0x80 3.0 100 8 14 ~1900 EXD-PTA-3.0x100 3.5 100 8 14 ~2200 EXD-PTA-3.5x100 4.0 100 9 16 ~2500 EXD-PTA-4.0x100 4.0 120 9 16 ~3000 EXD-PTA-4.0x120 4.5 120 9 16 ~3400 EXD-PTA-4.5x120 5.0 80 9 16 ~2000 EXD-PTA-5.0x80 5.0 120 9 16 ~3000 EXD-PTA-5.0x120 6.0 80 10 16 ~2200 EXD-PTA-6.0x80 6.0 120 10 16 ~3300 EXD-PTA-6.0x120 Diameter Range 7.0–12.0 mm (For bigger femoral/popliteal or iliac arteries)
Balloon Dia (mm) Balloon Length (mm) Nominal Pressure (atm) RBP (atm) Drug Load (μg) Product Code 7.0 60 8 14 ~2000 EXD-PTA-7.0x60 7.0 80 8 14 ~2600 EXD-PTA-7.0x80 7.0 120 9 16 ~3900 EXD-PTA-7.0x120 8.0 80 9 16 ~3000 EXD-PTA-8.0x80 8.0 120 9 16 ~4500 EXD-PTA-8.0x120 9.0 80 9 16 ~3400 EXD-PTA-9.0x80 9.0 120 9 16 ~5100 EXD-PTA-9.0x120 10.0 80 10 16 ~3800 EXD-PTA-10.0x80 10.0 120 10 16 ~5700 EXD-PTA-10.0x120 12.0 80 10 16 ~4600 EXD-PTA-12.0x80 12.0 120 10 16 ~6900 EXD-PTA-12.0x120 Paclitaxel-Iopromid Coating- Optimal Drug Delivery: Rapid paclitaxel release into the vessel wall upon balloon inflation aids in inhibiting neointimal hyperplasia.
- Stable Surface Layer: The specialized coating formulation resists delamination, ensuring controlled, uniform distribution of the antiproliferative agent.
Wide Balloon Diameter & Length Range- Diameter: 1.5 mm–12.0 mm covers small distal arteries up to larger peripheral segments.
- Length: 20 mm–220 mm addresses both short, focal lesions and extensive diseased vessel segments—reducing procedural device exchanges.
Low-Profile Catheter & Multiple Guidewire Compatibility- 5F Shaft Design: Minimizes access-site trauma, beneficial for challenging anatomies or smaller access routes.
- Guidewire Options: Accommodates 0.014”, 0.018”, or 0.035” wires, offering flexibility in diverse peripheral vascular lesions.
High Radiopacity for Accurate Placement- Pt-Ir Markers: Ensures clear, real-time balloon positioning under fluoroscopy, facilitating precise lesion coverage and drug deposition.
Varied Catheter Lengths- 80, 90, 120, 135, 150 cm: Multiple workable lengths allow operators to select the ideal configuration for femoral, popliteal, tibial, or other target vessels.
Productos relacionados
-
ATLAS Drug Eluting Coronary Stent System Cobalt Chromium
Leer másA cobalt-chromium coronary stent delivering durable radial strength y excellent trackability, suited for complex o calcified coronary lesions while ensuring minimal recoil.
-
DolphinPro Support Catheter
Leer másA crossing support catheter for complex peripheral or coronary lesions, featuring a reinforced shaft y hydrophilic coating to ease device delivery.
-
Stena Multi-Layer Flow Modulator for Peripheral
Leer másFlow-diverting stent for peripheral arteries, redistributing laminar flow away from diseased vessel segments, aiding aneurysm or side-branch preservation.
-
InWIRE Peripheral Guidewires
Leer másMultiple peripheral wire configurations (hydrophilic, stiff, exchange-length) facilitating safe crossing of complex or calcified lesions and ensuring stable device support.
















































































Contacto y asistencia
¿Cómo podemos ayudarle?
Antes de empezar, ¿qué es lo que mejor le describe?
Contacto y asistencia
Profesionales sanitarios
Formulario de consulta en línea
Para preguntas generales o relacionadas con el producto, rellene nuestro rápido formulario en línea. Recibirá una confirmación y un número de referencia para el seguimiento.
Consultas sobre productos
Apoyo clínico y de investigación
Formación y educación
Asistencia técnica
Contacto y asistencia
Pacientes y cuidadores
Formulario de consulta en línea
Para preguntas generales o relacionadas con el producto, rellene nuestro rápido formulario en línea. Recibirá una confirmación y un número de referencia para el seguimiento.
Uso y seguridad del producto
Pedidos y pagos
Asistencia y postratamiento
Contacto y asistencia
Proveedores y distribuidores
Formulario de consulta en línea
Para preguntas generales o relacionadas con el producto, rellene nuestro rápido formulario en línea. Recibirá una confirmación y un número de referencia para el seguimiento.
Asociación y contrato
Logística y transporte
Conformidad y documentación
Contacto y asistencia
Proveedores y distribuidores
Formulario de consulta en línea
Para preguntas generales o relacionadas con el producto, rellene nuestro rápido formulario en línea. Recibirá una confirmación y un número de referencia para el seguimiento.
Comunicados de prensa y noticias
Entrevistas y declaraciones
Eventos y conferencias
Contacto y asistencia
Otros / Consultas generales
Formulario de consulta en línea
Para preguntas generales o relacionadas con el producto, rellene nuestro rápido formulario en línea. Recibirá una confirmación y un número de referencia para el seguimiento.
Información general
Comentarios y sugerencias
Línea de asistencia HeadQuarter
- One World Trade Center, 285 Fulton Street. Nueva York, NY 10007, EE.UU.
- globalsales@invamed.com
- +1 (347) 535-0630