Placa CytroFIX® para húmero proximal (Copia)
High-Purity Titanium Constructs for Superior Clavicle Fracture Fixation
En CytroFIX® Superior Clavicula Plates by Cytronics (un INVAMED orthopedic brand) are meticulously engineered for superior approach fixation of clavicle fractures. Exclusively manufactured from high-purity titanium, these plates deliver robust stabilization, anatomical fit, and minimal soft tissue irritation. Whether addressing acute fractures, malunions, or osteotomies, these low-profile implants ensure reliable outcomes in surgical management of the clavicle.
Anatomically Shaped
Engineered curvature aligns with the superior aspect of the clavicle to optimize bone contact and reduce hardware prominence.
Titanio de gran pureza
Offers exceptional strength-to-weight ratio, biocompatibility, and corrosion resistance—ideal for fracture healing.
Geometría de perfil bajo
Minimizes implant palpability while maintaining rigidity for diverse fracture patterns.
Locking & Non-Locking Screw Options
Multi-hole design accommodates both locking and non-locking titanium screws, with variable-angle locking for complex fractures.
Broad Clinical Utility
Suitable for acute midshaft or lateral third fractures requiring a superior plating approach, as well as revision surgeries or nonunion fixation.
Contraindicaciones
Severe bone defects limiting fixation potential, active infection at the surgical site, patient conditions precluding surgery.
Especificaciones técnicas
Especificación | Detalle / Valor |
Nombre del producto | Placas CytroFIX® Superior Clavicula |
Material | High-Purity Titanium Alloy (e.g., Ti-6Al-4V ELI) |
Perfil de la placa | Low-profile, contoured for superior clavicle placement |
Mecanismo de bloqueo | Locking or non-locking titanium screws; optional variable-angle locking |
Diámetro del tornillo | 2.7 mm or 3.5 mm (titanium cortical screws, depending on hole specification) |
Espesor de la placa | ~2.0–2.5 mm (minimized profile) |
Hole Array | Multiple holes for bridging, compression, or combined fixation patterns |
Radiopacidad | Titanium visible on fluoroscopy (optional etched markers) |
Esterilidad | Provided non-sterile (autoclavable) or sterile, single use or reusable instrumentation (verify product line) |
Vida útil | Indefinite if stored properly; reusable within recommended inspection cycles |
Indicaciones clínicas | Midshaft/lateral clavicle fractures requiring superior plating, osteotomies, nonunion correction |
Cumplimiento de la normativa | Conforms to ISO 13485, CE/FDA (region-specific), meets orthopedic implant standards |
Matriz de tallas y pedidos
Longitud de la placa (mm) | Recuento de agujeros | Curvature | Tornillo compatible | Código del producto | Notas |
60 | 4 | Mild Superior Bend | 2,7 mm Bloqueo/no bloqueo | CFX-SCL-60-4-27-Ti | Shorter plate for smaller fractures in lateral or mid-shaft |
70 | 5 | Mild Superior Bend | 2,7 mm Bloqueo/no bloqueo | CFX-SCL-70-5-27-Ti | Cobertura ampliada para fracturas de leves a moderadas |
80 | 5 | Moderate Superior Bend | 2,7 o 3,5 mm Bloqueo | CFX-SCL-80-5-MX-Ti | Bridges midshaft fractures with variable-angle options |
90 | 6 | Moderate Superior Bend | 3,5 mm Bloqueo/no bloqueo | CFX-SCL-90-6-35-Ti | For larger or multi-fragment fractures requiring robust support |
100 | 7 | Enhanced Superior Contour | 3,5 mm Bloqueo/no bloqueo | CFX-SCL-100-7-35-Ti | Accommodates more complex or extended fracture lines |
110 | 8 | Enhanced Superior Contour | 3,5 mm Bloqueo/no bloqueo | CFX-SCL-110-8-35-Ti | Longest plate design for challenging multi-segment fractures |