Καθετήρας υποστήριξης DolphinPro
A υποστήριξη διέλευσης καθετήρα για σύνθετο περιφερικές ή στεφανιαίες αλλοιώσεις, που χαρακτηρίζονται από ενισχυμένος άξονας και υδρόφιλο επίστρωση για να διευκολύνει την παράδοση της συσκευής.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Broad Clinical Utility
Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
Αντενδείξεις
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Technical Specifications
| Προδιαγραφές | Λεπτομέρεια / Αξία |
| Όνομα προϊόντος | Καθετήρας υποστήριξης DolphinPro |
| Προβλεπόμενη χρήση | Lesion crossing and support in femoro-popliteal & BTK interventions |
| Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
| Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
| Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
| Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
| Συμβατότητα οδηγού σύρματος | Typically 0.014” or 0.018” (verify exact compatibility) |
| Ακτινοδιαπερατότητα | Radiopaque distal tip and markers for precise visualization |
| Στειρότητα | Provided sterile (single use) |
| Κλινικές ενδείξεις | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Size & Ordering Matrix
| Γαλλικά Μέγεθος | Usable Length (cm) | Guidewire | Tip Shape | Κωδικός προϊόντος | Σημειώσεις |
| 2.4 – 2.6 | 65 / 90 / 135 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
| 2.4 – 2.6 | 100 / 150 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
| 3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 6.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 7.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
Σχετικά προϊόντα
-

Atlas Ενδοαγγειακό περιφερικό μόσχευμα στεντ
Διαβάστε περισσότεραA καλυμμένο περιφερικό stent προσφορά μοσχεύματος ασφαλές απόφραξη ανευρυσμάτων ή αποφρακτικών βλαβών σε λαγόνιος ή μηριαίο τμημάτων, μειώνοντας τον κίνδυνο ρήξης ή επανέκφραξης.
-

Σύστημα αθηρεκτομής TemREN PRO
Διαβάστε περισσότεραTemREN PRO Σύστημα αθηρεκτομής; A περιστροφική ή κατευθυντικό συσκευή αθηρεκτομής εξειδικευμένη για αφαίρεση πλάκας στις περιφερικές αρτηρίες, ενισχύοντας lumen αποκατάσταση, ελαχιστοποιώντας παράλληλα το βαροτραύμα.
-

Συσκευή κλεισίματος AngioTEN
Διαβάστε περισσότεραA διαδερμική σύστημα αγγειακής σύγκλεισης για αρτηριακή ή φλεβική τοποθεσίες πρόσβασης, επιτρέποντας ασφαλές αιμόσταση μετά από καθετηριασμό ή επεμβατικές διαδικασίες.
-

Atlas Σύστημα στεφανιαίων στελεχών από ανοξείδωτο χάλυβα
Διαβάστε περισσότεραA ανοξείδωτο ατσάλι προσφορά στεφανιαίων stent στιβαρό δομική ακεραιότητα και εύκολο δυνατότητα παράδοσης για διαδερμικές στεφανιαίες επεμβάσεις ρουτίνας (PCI), εξισορροπώντας την αποδοτικότητα κόστους με την αξιόπιστη απόδοση.
