ThermoBLOCK System til radiofrekvensablation af åreknuder
A radiofrekvens ablationsplatform til inkompetent overfladiske vener, der tilbyder termisk lukning af saphena saphena eller perforerende vener for at lindre åreknuder symptomer.
Den Thermal Coagulation RF Ablation Generator er en avanceret, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy to ThermoBLOCK™ catheters og ThermoBLOCK™ stylets—enabling målrettet thermal ablation for chronic venous insufficiency (CVI). Equipped with a i realtid monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring sikker og consistent power application while protecting surrounding tissues.
Real-Time Feedback Control
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
Precision RF Delivery
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing og sealing of incompetent veins.
- Minimale følgeskader: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
User-Friendly Interface
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
Versatile Integration
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing og sealing of incompetent veins.
- Minimale følgeskader: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
Produktspecifikationer
Specifikation | Detalje / værdi |
Produktets navn | ThermoBLOCK Varicose Vein RF Ablation System |
Tilsigtet brug | Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins |
RF Catheter Design | 6–7F catheter with electrode segment near distal tip, temperature-controlled |
Nominal Power | ~10–30 W (depends on vein diameter and system setting) |
Catheter Length | ~60–120 cm (varies by code) |
Generator Compatibility | ThermoBLOCK RF Generator or universal 460 kHz system |
Temperature Monitoring | Integrated thermocouple in ablation segment |
Treatment Cycle | Typically ~20–40 seconds per segment, auto-regulated by temperature feedback |
Sterilitet | Steril, til engangsbrug |
Holdbarhed | ~2–3 years at 15–25 °C |
Kliniske indikationer | Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence |
Kontraindikationer | Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials |
Bestilling og størrelsesmatrix
Catheter Size (F) | Catheter Length (cm) | Ablation Segment (cm) | Produktkode | Noter |
6F | 60 | 7 | TBLK-6F-60-7 | Short catheter for small segments |
6F | 100 | 7 | TBLK-6F-100-7 | Standard ablation length, extended shaft |
7F | 100 | 10 | TBLK-7F-100-10 | Longer ablation segment for large GSV trunk |
7F | 120 | 10 | TBLK-7F-120-10 | For taller patients or more extensive reflux |
7F | 120 | 15 | TBLK-7F-120-15 | Extra ablation segment for major trunk veins |