Atlas koronar stent-system i rustfrit stål
A rustfrit stål udbud af koronar stent robust strukturel integritet og let til rutinemæssige perkutane koronarinterventioner (PCI), hvor der er balance mellem omkostningseffektivitet og pålidelig ydeevne.
Den ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Generelle produktspecifikationer
Specifikation | Detalje / værdi |
Produktets navn | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Materiale | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Design | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Leveringssystem | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Kompatibilitet med guidewire | 0.014” |
Indikationer | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Kontraindikationer | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Sterilitet | Steril (ethylenoxid) |
Engangsbrug | Ja |
Holdbarhed | 2–3 years (based on final packaging and coating, if any) |
Driftstemperatur | Recommended 15–25 °C for storage |
Detaljeret størrelsesbaseret bestilling og produktkoder
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Produktkode |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Relaterede varer
-
Extender Lægemiddeludvidende PTCA-ballonkateter Paclitaxel
Læs mereA paclitaxel-belagt koronar ballonkateter rettet mod reducere restenose under perkutan transluminal koronar angioplastik (PTCA), hvilket sikrer effektiv lægemiddelafgivelse til karvæggen.
-
Peta Sternal Closure Plate
Læs mereA titanium eller legering brystbenspladesystem, der giver stiv fiksering efter midtlinje sternotomi, hvilket forbedrer brystbensstabilitet og reducere risikoen for infektion eller dehiscens efter hjertekirurgi.
-
Hero LASER-system til fjernelse af bly
Læs mereA laserbaseret Ekstraktionsanordning, der muliggør præcis og sikker fjernelse af Hjerteafledninger (pacemaker eller ICD) i tilfælde af infektion, funktionsfejl i ledningen eller opgraderinger.
-
ATLAS Lægemiddeludvidende koronarstentsystem Kobolt-krom
Læs mereA kobolt-krom levering af koronar stent holdbar radial styrke og fremragende sporbarhed, velegnet til kompleks eller forkalket koronarlæsioner og samtidig sikre minimal rekyl.