AnkaCATH Neurovaskulært distalt adgangskateter
A distal adgang kateter specialiseret til neurovaskulær interventioner, der tilbyder forbedret Skubbarhed, sporbarhed og stabil mikrokateterstøtte i dybe cerebrale kar.
Navigate with Precision and Reach with Confidence Using the AnkaCATH
- AnkaCATH is designed for distal placement into the neurovasculature, providing intracranial support and a wide range of device compatibility.
Experience Superior Performance and Unmatched Access
- Exceptionally soft distal segment allows for excellent navigability and trackability into distal anatomy, enabling the AnkaCATH Catheter to provide support close to the treatment site.
Hybrid Design for Maximum Performance
- Hybrid Braid and Coil Design provides 1:1 push/pull control for enhanced trackability.
- Coil reinforcement provides lumen integrity, flexibility and excellent shape retention.
- Proximal variable pitch braid reinforcement provides support and torque control.

Torque Braid Overlay Provides Vital Torque Control
Sharpability
Stability
Coil
Design
Kink Resistance Inner Layer Braided
Navigate
- Material: Constructed with a durable, biocompatible Hybrid Braid and Coil Design for enhanced stability.
- Length: Extended sheath length to facilitate access to distal vascular territories.
- Flexibility: Engineered to provide optimal flexibility while maintaining structural integrity.
- Diameter Range: Available in various sizes to accommodate different procedural needs.
- Radiopacity: Enhanced radiopacity for improved visualization under imaging.
- Kink Resistance: Superior hybrid design offers excellent resistance to kinking and deformation.
- Hemostasis: Efficient hemostatic properties to minimize blood loss during procedures.
- Compatibility: Compatible with a wide range of interventional devices and guide wires.
- Length: Extended sheath length to facilitate access to distal vascular territories.
SUPERIOR
MICROCATHETER
PERFORMANCE
& RELIABLE DEVICE
DELIVERY
- High bending resistance with excellent torque control and optimum push through from proximal shaft to the distal end.
- Available in a variety of sizes, the AnkaCATH Catheter to diverse procedural requirements, ensuring a perfect fit for every patient.
- The enhanced radiopacity of the sheath allows for excellent visualization under imaging, aiding clinicians in precise navigation and placement.
- Unique hybrid braided design provides stability and support throughout the procedure, providing a sturdy yet flexible solution for expanded vascular access.
- This design contributes to the sheath’s exceptional bending resistance, maintaining integrity even in the most demanding situations.
- The rounded tip and flexible distal zone on the Distal Access Catheter are designed for confident advancement into fragile distal vessels.
- The design of Distal Access Catheter is designed for closer placement to the treatment site. Focus on the intervention, not access challenges.
Variable Stiffness & Braided Shaft
- PE/PEBAX Outer: Balances proximal rigidity for pushability with distal softness for atraumatic navigation in neurovasculature.
- Reinforced Design: A braided core ensures torsional stability, kink resistance, and secure device passage, even in sharply curved intracranial segments.
Non-Conical Large Lumen
- Generous Inner Diameter (0.071” – 0.075”): Accommodates multiple interventional devices or larger guidewires (up to 0.035”), reducing the need for multiple catheters.
- PTFE-Lined: Low-friction lumen supports smooth device transitions, crucial in time-sensitive stroke or aneurysm care.
Hydrofil distal belægning
- Friction Reduction: The final centimeters of the distal segment are coated with a slippery surface, easing catheter advancement or repositioning through challenging anatomies.
- Vessel Protection: Minimizes endothelial trauma and reduces the risk of vasospasm or dissection during repeated manipulations.
Radiopaque Marker & Visibility
- 1 mm Marker at 2 mm from the Distal Tip: Distinct fluoroscopic marking for precise tip placement, vital in intracranial interventions.
- Radiopaque Distal Segment: Facilitates continuous imaging guidance under X-ray to confirm safe navigation and device deployment.
Multiple Sizes & Lengths
- Proximal Profiles (4F, 5F, 6F): Offer varied support levels, addressing a range of patient anatomies and procedure complexities.
- Usable Lengths (90 cm, 120 cm): Suitable for short or extended vascular paths, from moderate to more proximal femoral/radial entry routes.
Universal Hub Connection
- Luer-Lok Hub: Securely attaches accessories (e.g., hemostatic valve, flush lines), ensuring steady control of infusions or device insertions.
Produktspecifikationer
Specifikation | Detalje / værdi |
Produktets navn | AnkaCATH Neurovaskulært distalt adgangskateter |
Tilsigtet brug | Facilitates distal access in neurovascular interventions (e.g., stroke thrombectomy, aneurysm coiling) |
Design af kateter | Braided or coiled shaft for torque and push, softer distal segment for atraumatic navigation |
Materiale | Pebax/Polyamid med forstærkning af rustfrit stål eller nitinol |
Udvendig diameter (F) | ~3F–5F (depending on product code) |
Indre lumen | Compatible with microcatheters (0.016–0.027” ID), or direct device passage |
Arbejdslængde | ~90–125 cm (varies by code) |
Tip-konfiguration | Soft, radiopaque distal tip, potentially hydrophilic coating |
Røntgentætte markører | 1–2 near distal zone for precise fluoroscopic tracking |
Sheath/Guide Compatibility | Typically 6F or 7F guide catheters for proximal support |
Sterilitet | Steril, til engangsbrug |
Holdbarhed | ~2–3 years if stored at 15–25 °C in sealed packaging |
Kliniske indikationer | Intracranial thrombectomy, aneurysm coiling, distal AVM catheterization |
Kontraindikationer | Extremely tortuous or stenotic intracranial vessels beyond feasible access, known device material allergy |
Bestilling og størrelsesmatrix
Udvendig diameter (F) | Arbejdslængde (cm) | Lumen ID (inch) | Produktkode | Noter |
3F | 90 | 0.016" | ANK-NV-3F-90-016 | Smaller OD for micro-aneurysm or distal stroke interventions |
3F | 105 | 0.016" | ANK-NV-3F-105-016 | Longer approach, same small lumen |
4F | 90 | 0.021" | ANK-NV-4F-90-021 | Common distal access for moderate neurovascular tasks |
4F | 105 | 0.021" | ANK-NV-4F-105-021 | Extended length for deeper intracranial navigation |
4F | 125 | 0.021" | ANK-NV-4F-125-021 | Max length for tall patients or complex anatomies |
5F | 105 | 0.027" | ANK-NV-5F-105-027 | Larger lumen for mechanical thrombectomy devices |
5F | 125 | 0.027" | ANK-NV-5F-125-027 | Maximum length plus wide ID for advanced neuro devices |
Relaterede varer
-
ATLAS Lægemiddeludvidende koronarstentsystem Kobolt-krom
Læs mereA kobolt-krom levering af koronar stent holdbar radial styrke og fremragende sporbarhed, velegnet til kompleks eller forkalket koronarlæsioner og samtidig sikre minimal rekyl.
-
GuideX Forlængerkateter
Læs mereEn forlængelse eller "mor-og-barn"-katetertilbud forbedret støtte og nå inden for snørklede eller distal koronare/perifere segmenter, hvilket muliggør stabil navigation af enheden.
-
Pars Aftageligt emboliseringskateter
Læs mereA kateter Systemaktivering selektiv fremføring af mikrokateter og mekanisk eller kemisk embolisering med en distal aftagelig Tip til at undgå, at kateteret kommer i klemme.
-
Libro Ikke-klæbende emboliseringsmiddel: EVOH, DMSO og tantal
Læs mereA ikke klæbende flydende embolisk system, der kombinerer EVOH, DMSO og tantal til kontrolleret devaskularisering af AVM'er eller tumor fødekarrene, hvilket sikrer en præcis indsættelse uden permanent fastholdelse af karrene.