Atlas Venous Stent
A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
Na stránkách Atlas™ Venous Stent, introduced by Invamed-a globální výrobce zdravotnických prostředků—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a samorozšiřující se nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting trvanlivé patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Kontraindikace
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Specifikace | Detail / Hodnota |
Název produktu | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Mechanismus nasazení | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Radiální síla | Moderate to high, designed to resist extrinsic compression |
Rozsah průměrů stentů | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Radioprůhledné značky | Proximal and distal markers for fluoroscopic visualization |
Sterilita | Sterile, single use |
Doba použitelnosti | ~3–5 years if stored at 15–25 °C |
Klinické indikace | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Kód produktu | Poznámky |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Související produkty
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Čtěte víceA rotational system featuring a leaf tip design for mechanical clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
Viper™ Valved Infusion Catheters
Čtěte víceNa stránkách Viper™ Valved Infusion Catheter je single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with nebo without a guidewire in place.
-
InWIRE Peripheral Guidewires
Čtěte víceMultiple periferie wire configurations (hydrophilic, stiff, exchange-length) facilitating bezpečný crossing of complex or calcified lesions and ensuring stable device support.
-
VascuVac Ai Assisted Vacuum Thrombectomy Technologies
Čtěte víceAn innovative system utilizing AI-assisted technology for efficient vacuum thrombectomy, designed to rapidly remove thrombi from blood vessels, restore blood flow, a minimize procedural risks in vascular interventions.