Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
An over-the-wire (OTW) device merging rotational disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE daxili astar
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Məhsulun spesifikasiyası
Spesifikasiya | Detal / Dəyər |
Məhsulun adı | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Nəzərdə tutulan istifadə | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Kateter Dizaynı | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Xarici diametri (F) | ~5–7F, depending on model |
İş Uzunluğu | ~80–120 cm (varies by product code) |
Bələdçi telinin Uyğunluğu | Typically 0.035” (OTW approach) |
Sterillik | Steril, tək istifadə |
Raf Ömrü | Möhürlənmiş qablaşdırmada 15-25 °C temperaturda ~2-3 il |
Klinik göstərişlər | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Əks göstərişlər | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Sifariş və Ölçü Matrisi
Xarici diametri (F) | İş uzunluğu (sm) | Curve Tip Configuration | Məhsul Kodu | Qeydlər |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Əlaqədar məhsullar
-
Viper™ Valved Infusion Catheters
Daha ətraflı oxuyunThe Viper™ Valved Infusion Catheter a single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with və ya without a guidewire in place.
-
VenoNeedle® Kiçik Damar RF Ablasiyası Sistemi
Daha ətraflı oxuyunA aşağı güc istilik sistemi hədəflənir hörümçək damarları, telenjiektaziyalar və ya kiçik retikulyar varikozlarla dəqiq laxtalanma, böyük kəsiklərdən və ya uzun müddət dayanmadan qaçınmaq.
-
Mantis XP Thrombectomy System for Fistula
Daha ətraflı oxuyunA high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
-
Viper ULTRA Thrombolysis Catheter