Fistula üçün Mantis XP Trombektomiya Sistemi
A yüksək güclü dərin venoz və ya arterial tıkanıklıqlar üçün mexaniki trombektomiya aparatı, mürəkkəb anatomiyalarda genişlənmiş əlçatanlığı və möhkəm laxtanın çıxarılmasını dəstəkləyir.
The Mantis XP a pharmacomechanical thrombectomy system specifically engineered for dialysis native AV fistulae. Featuring a fırlanma catheter design and sinusoidal wave geometry, Mantis XP enables rapid və efficient clot disruption, infusion, and evacuation in a single pass—helping to restore patency while minimuma endirilməsi potential vessel trauma in end-stage renal disease (ESRD) patients requiring continuous dialysis access.
Rotational Thrombectomy Mechanism
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
Extended Infusion Zone
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
Variable Catheter Length & Profile
- Uzunluqlar: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
Nitinol & PA/PEBAX Construction
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
Radiopacity & Visibility
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip üçün proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
- Uzunluqlar: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip üçün proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
Məhsulun spesifikasiyası
Spesifikasiya | Detal / Dəyər |
Məhsulun adı | Mantis XP Thrombectomy System |
Nəzərdə tutulan istifadə | High-powered mechanical thrombectomy in venous or arterial occlusions, removing large or organized clot |
Kateter Dizaynı | Rotational shaft with extended reach (“XP”), integrated aspiration lumen or side port |
Material | Stainless steel or nitinol core, polymer outer sheath |
Rotational Speed Range | ~50k–120k rpm (verify final) |
Xarici diametri (F) | ~6–8F (depending on model) |
İş Uzunluğu | ~80–120 cm (varies by product code) |
Bələdçi telinin Uyğunluğu | Typically 0.035” |
Sterillik | Steril, tək istifadə |
Raf Ömrü | ~2–3 years if stored at 15–25 °C in sealed packaging |
Klinik göstərişlər | Large clot burdens in major peripheral veins/arteries, deep venous thrombosis (DVT), acute limb ischemia |
Əks göstərişlər | Extremely tortuous vessels, heavily calcified segments, or known sensitivity to device materials |
Sifariş və Ölçü Matrisi
Xarici diametri (F) | İş uzunluğu (sm) | İpucu Konfiqurasiyası | Məhsul Kodu | Qeydlər |
6F | 80 | Standard Rotational Tip | MNT-XP-6F-80-SR | Smaller OD for moderate clot loads |
6F | 100 | Leaf Tip | MNT-XP-6F-100-LF | Intermediate length, specialized tip for large clot |
7F | 80 | Standard Rotational Tip | MNT-XP-7F-80-SR | Larger OD for heavier clot burden |
7F | 120 | Leaf Tip | MNT-XP-7F-120-LF | Extended shaft + specialized tip for extensive occlusions |
8F | 100 | Standard Rotational Tip | MNT-XP-8F-100-SR | Max diameter & high rotational power for dense clots |
8F | 120 | Leaf Tip | MNT-XP-8F-120-LF | Extended length + leaf tip for severe multi-segment thrombosis |
Əlaqədar məhsullar
-
Dovi Trombus Ultra Aspirasiya Kateteri
Daha ətraflı oxuyunA yüksək vakuum üçün aspirasiya kateteri kəskin və ya yarımkəskin arterial və ya venoz yataqlarda trombüsün çıxarılması, minimal parçalanma riski ilə sürətli revaskulyarizasiyanın təmin edilməsi.
-
NOD Valvulotom
Daha ətraflı oxuyunA titan və ya ərintisi döş lövhəsi sistemini təmin edir sərt fiksasiya post-orta xətt sternotomiya, gücləndirilməsi sternum sabitliyi və ürək cərrahiyyəsindən sonra infeksiya və ya dehissensiya risklərinin azaldılması.
-
VascuVac Ai Yardımlı Vakuum Trombektomiya Texnologiyaları
Daha ətraflı oxuyunEffektiv vakuum trombektomiyası üçün süni intellektlə dəstəklənən texnologiyadan istifadə edən innovativ sistem. trombları sürətlə çıxarın qan damarlarından, qan axını bərpa etmək, və prosedur risklərini minimuma endirmək damar müdaxilələrində.
-
Venablock ™ Varikoz Damarlarının Müalicəsi Damarların Bağlanması Sistemi
Daha ətraflı oxuyunVenablock ™ Varikoz Damarlarının Müalicəsi Damarların Bağlanması Sistemi; A siyanoakrilat əsaslı üçün damarların bağlanması sistemi səthi venoz bacarıqsızlıq, çatdırılma qeyri-termal minimal lokal anesteziya ilə oklüziya və sürətli prosedurdan sonrakı bərpa.