Atlas Venous Stent
A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
إن Atlas™ Venous Stent, introduced by إنفاميد-a الشركة العالمية المصنعة للأجهزة الطبية—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a التوسيع الذاتي nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting متينة patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
موانع الاستعمال
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
المواصفات | التفاصيل / القيمة |
اسم المنتج | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
آلية النشر | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
القوة الشعاعية | Moderate to high, designed to resist extrinsic compression |
نطاق قطر الدعامة | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
العلامات المشعة | Proximal and distal markers for fluoroscopic visualization |
العقم | Sterile, single use |
مدة الصلاحية | ~3–5 years if stored at 15–25 °C |
المؤشرات السريرية | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | رمز المنتج | الملاحظات |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
منتجات ذات صلة
-
NOD Valvulotome
قراءة المزيدA تيتانيوم أو سبيكة نظام الصفيحة القصية الذي يوفر جامدة التثبيت بعد بضع القص في منتصف الخط الوسطي، وتعزيز الثبات القصي وتقليل مخاطر الإصابة بالعدوى أو النزف بعد جراحة القلب.
-
Dovi قسطرة شفط الخثرة الفائقة
قراءة المزيدA التفريغ العالي قسطرة الشفط من أجل حاد أو تحت الحاد إزالة الخثرة في القاع الشرياني أو الوريدي، مما يضمن إعادة توعية سريعة مع الحد الأدنى من مخاطر التفتت.
-
Peta تخفيف الضغط الميكانيكي عن طريق الجلد للقرص Peta
قراءة المزيدصُمم هذا الجهاز المصمم بمواد مصممة بدقة متناهية ليتيح تخفيف الضغط الفعال على الأقراص المنفتقة وتخفيف الضغط على الأعصاب في العمود الفقري وتخفيف الألم مع تعزيز التعافي بشكل أسرع.
-
نظام تحليل الخثرة Inca Trellis Trellis
قراءة المزيدA القسطرة التوصيل حال للجلطات وكلاء بينما الفلتر تمنع الحماية من الانصمام القاصي، مما يضمن انحلالًا دوائيًا أكثر أمانًا للجلطات.